South Western Railway - Karnataka
37648354 supply of unified notice for fire prevention and safety to drg no.icf / std 6 4 022, alt l / nil. [ warranty period: 30 months after the date of delivery ] => limited...
37648354 supply of unified notice for fire prevention and safety to drg no.icf / std 6 4 022, alt l / nil. [ warranty period: 30 months after the date of delivery ] => limited...
37533063 supply of unified notice for fire prevention and safety to drg no.icf / std 6 4 022, alt l / nil. => limited...
37034118 design, manufacture, testing, inspection and supply of 7 nos. of 20 mva 110/33 11kv power transformers along with nitrogen injection fire protection systems conforming to kptcl technical specifications, f.o.r.d at store/site basis, including insurance, transportation and unloading. , design, manufacture, testing, inspection and supply of 20 mva, 110/33 11kv, delta/star, core type, 3 phase, 50 hz, out door type, oil immersed, onan/onaf cooled power transformer complete with cooler bank, oltc components suitable for voltage variation of +5% to 15%, rtcc panel along with all fittings & accessories and transformer oil for 1st filling plus 10% extra oil in non returnable drums with terminal connectors conforming to kptcl technical specifications.,supply of complete set of equipment for fire prevention & extinguishing system by nitrogen (n2) injection method as per technical specification including supply of all control & accessories, pipe, connectors required control cables etc. all complete for above transformers....
36292573 supply of self adhesive vinyl stickerself adhesive vinyl sticker, digital printed superior quality self adhesive vinyl sticker for fire prevention and safety, a3 size of 3m or avery dennison or orajet or lg make as per the sample attached. [ warranty period: 9 months after the date of delivery ] => limited...
36175008 design, manufacture, testing, inspection and supply of 15 nos. of 20 mva 110 / 33 11kv power transformers along with nitrogen injection fire protection systems conforming to kptcl technical specifications, f.o.r.d at store / site basis, including insurance, transportation and unloading. , design, manufacture, testing, inspection and supply of 20 mva, 110 / 33 11kv, delta / star, core type, 3 phase, 50 hz, out door type, oil immersed, onan / onaf cooled power transformer complete with cooler bank, oltc components suitable for voltage variation of +5% to 15%, rtcc panel along with all fittings & accessories and transformer oil for 1st filling plus 10% extra oil in non returnable drums with terminal connectors conforming to kptcl technical specifications., supply of complete set of equipment for fire prevention & extinguishing system by nitrogen ( n2 ) injection method as per technical specification including supply of all control & accessories, pipe, connectors required control cables etc. all complete for above transformers....
34879165 design, manufacture, testing, inspection, supply of 02 nos. of 31.5mva, 66 / 11kv power transformers along with nitrogen injection fire protection systems conforming to kptcl technical specifications, f.o.r.d at store / site basis, including insurance, transportation and unloading. , design, manufacture, testing, inspection and supply of 31.5 mva, 66 / 11kv, delta / star, core type, 3 phase, 50 hz, out door type, oil immersed, onan / onaf cooled power transformer complete with cooler bank, oltc components suitable for voltage variation of +5% to 15%, rtcc panel along with all fittings & accessories, itcs and transformer oil for 1st filling plus 10% extra oil in non returnable drums with terminal connectors conforming to kptcl technical specifications., supply of complete set of equipment for fire prevention & extinguishing system by nitrogen ( n2 ) injection method as per technical specification including supply of all control & accessories, pipe, connectors required control cables etc all complete for above transformers....
34879163 design, manufacture, testing, inspection and supply of 15 nos. of 20 mva 110 / 33 11kv power transformers along with nitrogen injection fire protection systems conforming to kptcl technical specifications, f.o.r.d at store / site basis, including insurance, transportation and unloading. , design, manufacture, testing, inspection and supply of 20 mva, 110 / 33 11kv, delta / star, core type, 3 phase, 50 hz, out door type, oil immersed, onan / onaf cooled power transformer complete with cooler bank, oltc components suitable for voltage variation of +5% to 15%, rtcc panel along with all fittings & accessories and transformer oil for 1st filling plus 10% extra oil in non returnable drums with terminal connectors conforming to kptcl technical specifications., supply of complete set of equipment for fire prevention & extinguishing system by nitrogen ( n2 ) injection method as per technical specification including supply of all control & accessories, pipe, connectors required control cables etc all complete for above transformers....
34879161 design, manufacture, testing, inspection and supply of 15 nos. of 20mva, 66 / 11kv power transformers along with nitrogen injection fire protection systems conforming to kptcl technical specifications, f.o.r.d at store / site basis, including insurance, transportation and unloading. , design, manufacture, testing, inspection and supply of 20 mva, 66 / 11kv, delta / star, core type, 3 phase, 50 hz, out door type, oil immersed, onan / onaf cooled power transformer complete with cooler bank, oltc components suitable for voltage variation of +5% to 15%, rtcc panel along with all fittings & accessories and transformer oil for 1st filling plus 10% extra oil in non returnable drums with terminal connectors conforming to kptcl technical specifications., supply of complete set of equipment for fire prevention & extinguishing system by nitrogen ( n2 ) injection method as per technical specification including supply of all control & accessories, pipe, connectors required control cables etc all complete for above transformers....
34879160 design, manufacture, testing, inspection and supply of 08 nos. of 12.5mva, 66 / 11kv power transformers along with nitrogen injection fire protection systems conforming to kptcl technical specifications, f.o.r.d at store / site basis, including insurance, transportation and unloading. , design, manufacture, testing, inspection and supply of 12.5 mva, 66 / 11kv, delta / star, core type, 3 phase, 50 hz, out door type, oil immersed, onan cooled power transformer complete with oltc components suitable for voltage variation of +5% to 15%, rtcc panel along with all fittings & accessories and transformer oil for 1st filling plus 10% extra oil in non returnable drums with terminal connectors, conforming to kptcl technical specifications., supply of complete set of equipment for fire prevention & extinguishing system by nitrogen ( n2 ) injection method as per technical specification including supply of all control & accessories, pipe, connectors required control cables etc all complete for above transformers....
33140839 supply of unified notice for fire preventionunified notice for fire prevention,unified notice for fire prevention and safety to drg no.icf/std 6 4 022, alt l/nil....
33125836 supply of unified notice for fire prevention and safetyunified notice for fire prevention and safety,unified notice for fire prevention and safety to drg no.icf/std 6 4 022, alt l/nil. => limited...
30345972 estimate for maintenance of older plantation forest fire prevention work watch & ward etc at mamadapur 35.00 ha fsy no.390 p & 345 ...
30345970 estimate for maintenance of older plantation forest fire prevention work watch & ward etc at benal 24.52 ha fsy no: 221 & almatti ...
30058876 supply of unified notice for fire prevention and safety.unified notice for fire prevention and safety.,unified notice for fire prevention and safety, as per rdso drg. no: rdso/sk k3028, alt 3....
29979233 provision of high mast light at eti afs and fire prevention infrastructure in various labs at eti afs under ge m af jalahalli bangalore...
29664852 bids are invited for nitrogen injection fire prevention and extinguishing system for oil filled transformer total quantity : 47...
28452976 design, manufacture, testing, inspection, supply of 17 nos of 20mva, 66/11kv power transformers along with nitrogen injection fire protection systems conforming to kptcl technical specifications, f.o.r.d at store/site basis, including insurance, transportation and unloading. 1. design, manufacture, testing, inspection, supply of 20mva 66/11kv, delta/star, core type, 3 phase, 50 hz, out door type, oil immersed, onan, onaf cooled power transformer complete with oltc components suitable for voltage variation of +5% to 15%, rtcc panel along with all fittings & accessories and transformer oil for 1st filling plus 10% extra oil in non returnable drums as per requirement of kptcl specification with terminal connectors ., 2. complete set of equipment for fire prevention and extinguishing system by nitrogen(n2) injection method as per technical specification including supply of all control and accessories, pipe, connectors, required control cables etc all complete for above transformers., ...
28452975 design, manufacture, testing, inspection, supply of 9 nos of 12.5mva, 66/11kv power transformers along with nitrogen injection fire protection systems conforming to kptcl technical specifications, f.o.r.d at store/site basis, including insurance, transportation and unloading. 1. design, manufacture, testing, inspection, supply of 12.5mva 66/11kv, delta/star, core type, 3 phase, 50 hz, out door type, oil immersed, onan cooled power transformer complete with oltc components suitable for voltage variation of +5% to 15%, rtcc panel along with all fittings & accessories and transformer oil for 1st filling plus 10% extra oil in non returnable drums as per requirement of kptcl specification with terminal connectors ., 2. complete set of equipment for fire prevention & extinguishing system by nitrogen (n2) injection method as per technical specification including supply of all control & accessories, pipe, connectors required control cables etc all complete for above transformers., ...
28452973 design, manufacture, testing, inspection, supply of 23 nos of 20mva, 110/33 11kv power transformers along with nitrogen injection fire protection systems conforming to kptcl technical specifications, f.o.r.d at store/site basis, including insurance, transportation and unloading. 1. design, manufacture, testing, inspection, supply of 20mva 110/33 11kv, delta/star, core type, 3 phase, 50 hz, out door type, oil immersed, onan, onaf cooled power transformer complete with oltc components suitable for voltage variation of +5% to 15%, rtcc panel along with all fittings & accessories and transformer oil for 1st filling plus 10% extra oil in non returnable drums as per requirement of kptcl specification with terminal connectors ., 2. complete set of equipment for fire prevention & extinguishing system by nitrogen (n2) injection method as per technical specification including supply of all control & accessories, pipe, connectors required control cables etc all complete for above transformers., ...
25692795 supply of , unified notice for fire prevention & safety along with adhesive sticking. as per rdso sk k3028, alt 3 or latest....
24990110 design, manufacture, testing, inspection, supply of 04 nos of 100mva, 220/110/11kv auto transformers along with nitrogen injection fire protection systems conforming to kptcl technical specifications, f.o.r.d at store/site basis, including insurance, transportation and unloading. 1. design, manufacture, testing, inspection, supply of 100 mva, 220/110/11kv, yna0d11, core type, 3 phase, 50 hz, out door type, oil immersed, onan/onaf/ofaf cooled power transformer complete with cooler bank, oltc components suitable for voltage variation of +5% to 15%, rtcc panel along with all fittings & accessories, itcs and transformer oil for 1st filling plus 10% extra oil in non returnable drums as per requirement of this specification with terminal connectors conforming to kptcl technical specifications. f.o.r.d at store/site basis, including insurance, transportation and unloading, 2. complete set of equipment for fire prevention & extinguishing system by nitrogen (n2) injection method as per technical specification including supply of all control & accessories, pipe, connectors required control cables etc all complete for above transformers., ...
24989775 design, manufacture, testing, inspection, supply of 02 nos of 12.5mva, 66/33 11kv power transformers along with nitrogen injection fire protection systems conforming to kptcl technical specifications, f.o.r.d at store/site basis, including insurance, transportation and unloading. 1. design, manufacture, testing, inspection, supply of 12.5mva, 66/33 11kv, delta/star, core type, 3 phase, 50 hz, out door type, oil immersed, onan cooled power transformer complete with cooler bank, oltc components suitable for voltage variation of +5% to 15%, rtcc panel along with all fittings & accessories and transformer oil for 1st filling plus 10% extra oil in non returnable drums as per requirement of this specification with terminal connectors including supervision of erection and commissioning and conforming to kptcl technical specifications. f.o.r.d at store/site basis, including insurance, transportation and unloading., 2. complete set of equipment for fire prevention & extinguishing system by nitrogen (n2) injection method as per technical specification including supply of all control & accessories, pipe, connectors required control cables etc all complete for above transformers., ...
24989774 design, manufacture, testing, inspection, supply of 9 nos of 31.5mva, 66/11kv power transformers along with nitrogen injection fire protection systems conforming to kptcl technical specifications, f.o.r.d at store/site basis, including insurance, transportation and unloading. 1. design, manufacture, testing, inspection, supply of 31.5 mva, 66/11kv, delta/star, core type, 3 phase, 50 hz, out door type, oil immersed, onan/onaf, cooled power transformer complete with cooler bank, oltc components suitable for voltage variation of +5% to 15%, rtcc panel along with all fittings & accessories, itcs and transformer oil for 1st filling plus 10% extra oil in non returnable drums as per requirement of this specification with terminal connectors including supervision of erection and commissioning and conforming to kptcl technical specifications. f.o.r.d at store/site basis, including insurance, transportation and unloading., 2. complete set of equipment for fire prevention & extinguishing system by nitrogen (n2) injection method as per technical specification including supply of all control & accessories, pipe, connectors required control cables etc all complete for above transformers., ...
24989766 design, manufacture, testing, inspection, supply of 26 nos of 20mva, 110/33 11kv power transformers along with nitrogen injection fire protection systems conforming to kptcl technical specifications, f.o.r.d at store/site basis, including insurance, transportation and unloading. 1. design, manufacture, testing, inspection, supply of 20 mva, 110/33 11kv, delta/star, core type, 3 phase, 50 hz, out door type, oil immersed, onan/onaf, cooled power transformer complete with cooler bank, oltc components suitable for voltage variation of +5% to 15%, rtcc panel along with all fittings & accessories and transformer oil for 1st filling plus 10% extra oil in non returnable drums as per requirement of this specification with terminal connectors including supervision of erection and commissioning and conforming to kptcl technical specifications. f.o.r.d at store/site basis, including insurance, transportation and unloading., 2. complete set of equipment for fire prevention & extinguishing system by nitrogen (n2) injection method as per technical specification including supply of all control & accessories, pipe, connectors required control cables etc all complete for above transformers., ...
24989730 design, manufacture, testing, inspection, supply of 9 nos of 20mva, 66/11kv power transformers along with nitrogen injection fire protection systems conforming to kptcl technical specifications, f.o.r.d at store/site basis, including insurance, transportation and unloading. 1. design, manufacture, testing, inspection, supply of 20 mva, 66/11kv, delta/star, core type, 3 phase, 50 hz, out door type, oil immersed, onan/onaf, cooled power transformer complete with cooler bank, oltc components suitable for voltage variation of +5% to 15%, rtcc panel along with all fittings & accessories and transformer oil for 1st filling plus 10% extra oil in non returnable drums as per requirement of this specification with terminal connectors including supervision of erection and commissioning and conforming to kptcl technical specifications. f.o.r.d at store/site basis, including insurance, transportation and unloading., 2. complete set of equipment for fire prevention & extinguishing system by nitrogen (n2) injection method as per technical specification including supply of all control & accessories, pipe, connectors required control cables etc all complete for above transformers., ...
24989728 design, manufacture, testing, inspection, supply of 12 nos of 12.5mva, 66/11kv power transformers along with nitrogen injection fire protection systems conforming to kptcl technical specifications, f.o.r.d at store/site basis, including insurance, transportation and unloading. 1. design, manufacture, testing, inspection, supply of 12.5 mva, 66/11kv, delta/star, core type, 3 phase, 50 hz, out door type, oil immersed, onan cooled power transformer complete with oltc components suitable for voltage variation of +5% to 15%, rtcc panel along with all fittings & accessories and transformer oil for 1st filling plus 10% extra oil in non returnable drums as per requirement of this specification with terminal connectors and conforming to kptcl technical specifications. f.o.r.d at store/site basis, including insurance, transportation and unloading., 2. complete set of equipment for fire prevention & extinguishing system by nitrogen (n2) injection method as per technical specification including supply of all control & accessories, pipe, connectors required control cables etc all complete for above transformers., ...
24989612 design, manufacture, testing, inspection, supply of 01 no of 150mva, 220/66/11kv power transformers along with nitrogen injection fire protection systems conforming to kptcl technical specifications, f.o.r.d at store/site basis, including insurance, transportation and unloading. 1. design, manufacture, testing, inspection, supply of 150 mva, 220/66/11kv, ynyn0d11, core type, 3 phase, 50 hz, out door type, oil immersed, onan/onaf/ofaf cooled power transformer complete with cooler bank, oltc components suitable for voltage variation of +5% to 15%, rtcc panel along with all fittings & accessories, itcs and transformer oil for 1st filling plus 10% extra oil in non returnable drums as per requirement of this specification with terminal connectors conforming to kptcl technical specifications. f.o.r.d at store/site basis, including insurance, transportation and unloading, 2. complete set of equipment for fire prevention & extinguishing system by nitrogen (n2) injection method as per technical specification including supply of all control & accessories, pipe, connectors required control cables etc all complete for above transformers., ...
24177721 design, manufacture, testing, inspection, supply of 15 nos of 20mva, 110/33 11kv power transformers along with nitrogen injection fire protection systems conforming to kptcl technical specifications, f.o.r.d at store/site basis, including insurance, transportation and unloading. 1. design, manufacture, testing, inspection, supply of 20 mva, 110/33 11kv, delta/star, core type, 3 phase, 50 hz, out door type, oil immersed, onan cooled power transformer complete with cooler bank, oltc components suitable for voltage variation of +5% to 15%, rtcc panel along with all fittings & accessories and transformer oil for 1st filling plus 10% extra oil in non returnable drums as per requirement of this specification with terminal connectors conforming to kptcl technical specifications. f.o.r.d at store/site basis, including insurance, transportation and unloading., 2. complete set of equipment for fire prevention & extinguishing system by nitrogen (n2) injection method as per technical specification including supply of all control & accessories, pipe, connectors required control cables etc all complete for above transformers., ...
24177711 design, manufacture, testing, inspection, supply of 9 nos of 20mva, 66/11kv power transformers along with nitrogen injection fire protection systems conforming to kptcl technical specifications, f.o.r.d at store/site basis, including insurance, transportation and unloading 1. design, manufacture, testing, inspection, supply of 20 mva, 66/11kv, delta/star, core type, 3 phase, 50 hz, out door type, oil immersed, onan, cooled power transformer complete with cooler bank, oltc components suitable for voltage variation of +5% to 15%, rtcc panel along with all fittings & accessories and transformer oil for 1st filling plus 10% extra oil in non returnable drums as per requirement of this specification with terminal connectors including supervision of erection and commissioning and conforming to kptcl technical specifications. f.o.r.d at store/site basis, including insurance, transportation and unloading., 2. complete set of equipment for fire prevention & extinguishing system by nitrogen (n2) injection method as per technical specification including supply of all control & accessories, pipe, connectors required control cables etc all complete for above transformers., ...
23359504 supply of ss unified notice for fire prevention, ss unified notice for fire prevention & safety to drg. no.icf/std 64 045,item 1, alt nil....
23176447 design, manufacture, testing, inspection, supply of 10 nos of 20mva, 66/11kv power transformers along with nitrogen injection fire protection systems conforming to kptcl technical specifications, f.o.r.d at store/site basis, including insurance, transportation and unloading. 1. design, manufacture, testing, inspection, supply of 20 mva, 66/11kv, delta/star, core type, 3 phase, 50 hz, out door type, oil immersed, onan, cooled power transformer complete with cooler bank, oltc components suitable for voltage variation of +5% to 15%, rtcc panel along with all fittings & accessories and transformer oil for 1st filling plus 10% extra oil in non returnable drums as per requirement of this specification with terminal connectors including supervision of erection and commissioning and conforming to kptcl technical specifications. f.o.r.d at store/site basis, including insurance, transportation and unloading., 2. complete set of equipment for fire prevention & extinguishing system by nitrogen (n2) injection method as per technical specification including supply of all control & accessories, pipe, connectors required control cables etc all complete for above transformers., ...
23176305 design, manufacture, testing, inspection, supply of 15 nos of 20mva, 110 / 33 11kv power transformers along with nitrogen injection fire protection systems conforming to kptcl technical specifications, f.o.r.d at store / site basis, including insurance, transportation and unloading. 1. design, manufacture, testing, inspection, supply of 20 mva, 110 / 33 11kv, delta / star, core type, 3 phase, 50 hz, out door type, oil immersed, onan cooled power transformer complete with cooler bank, oltc components suitable for voltage variation of +5% to 15%, rtcc panel along with all fittings & accessories and transformer oil for 1st filling plus 10% extra oil in non returnable drums as per requirement of this specification with terminal connectors conforming to kptcl technical specifications. f.o.r.d at store / site basis, including insurance, transportation and unloading., 2. complete set of equipment for fire prevention & extinguishing system by nitrogen ( n2 ) injection method as per technical specification including supply of all control & accessories, pipe, connectors required control cables etc all complete for above transformers., ...
23176281 design, manufacture, testing, inspection, supply of 02 nos of 31.5 mva, 66/11kv power transformers along with nitrogen injection fire protection systems conforming to kptcl technical specifications, f.o.r.d at store/site basis, including insurance, transportation and unloading. 1. design, manufacture, testing, inspection, supply of 31.5 mva, 66/11kv, delta/star, core type, 3 phase, 50 hz, out door type, oil immersed, onan, cooled power transformer complete with cooler bank, oltc components suitable for voltage variation of +5% to 15%, rtcc panel along with all fittings & accessories, itcs and transformer oil for 1st filling plus 10% extra oil in non returnable drums as per requirement of this specification with terminal connectors including supervision of erection and commissioning and conforming to kptcl technical specifications. f.o.r.d at store/site basis, including insurance, transportation and unloading., 2. complete set of equipment for fire prevention & extinguishing system by nitrogen (n2) injection method as per technical specification including supply of all control & accessories, pipe, connectors required control cables etc all complete for above transformers., ...
21807363 supply of unified notice for fire prevention and safety., unified notice for fire prevention and safety to drg no.icf/std 6 4 022, alt l/nil....
21262293 tender for unified notice for fire prevention and safetyitem list : (1) unified notice for fire prevention and safety with adhesive sticking along aluminium foil as perrdso sk k 3028 alt 3 or latest....
20658855 tender for unified notice for fire prevention and safety to drg no.icf/std 6 4 022, alt l/nil.item list : (1) unified notice for fire prevention and safety to drg no.icf/std 6 4 022, alt l/nil....
20583882 tender for unified notice for fire prevention and safety as per rdso drg. no. sk k 3028, alt 3 or latest.item list : (1) unified notice for fire prevention and safety, as per rdso drg.no. sk k 3028 alt 3 or latest....
20234592 tender for unified notice for fire prevention safety as per rdso drg sk k 3028 alt 3 item list : ( 1 ) unified notice for fire prevention and safety, as per rdso drg.no. sk k 3028 alt 3 or latest....
18020545 tender for unified notice for fire prevention and safety to drg no.icf/std 6 4 022, alt l/nil....
16333874 tender for unified notice for fire prevention and safety, as per rdso sk k 3028 alt 3 orlatest. note:adhesive to be strong bonded for pasting...
14349287 supply of unified notice for fire prevention and safety to drg no.icf/std 6 4 022, alt. i/nil....
14345653 supply of unified notice for fire prevention and safety to drg no.icf/std 6 4 022, alt. i/nil....
14005383 tender for supply , supervision of erection and commissioning of nitrogen injection fire prevention and extinguishing system...
11632264 providing fire prevention and fire fighting measure for office of the principal account general a and e, bangalore....
11128651 unified notice for fire prevention and safety to drg no.icf/std 6 4 022, alt l/nil....
11109468 unified notice for fire prevention and safety to drg no. icf std 6 4 022 alt l/nil...
10839648 unified notice for fire prevention and safety to drg no.icf/std 6 4 022, alt l/nil....
10424072 design, manufacturing, testing, supply and installation and commissioning of 3 sets of nitrogen injection fire prevention and extinguishing systems ( nfes ) to power transformers conforming to kptcl technical specifications, f.o.r.d at store / site basis, including unloading, insurance and transportation...
10410480 design , manufacture , testing , supply , installation and communication of three sets of nitrogen injection fire prevention and extinguishing systems to power transformers conforming to kptcl technical specifications, ford...
9471746 unified notice for fire prevention and safety, asper rdso drg no. sk k 3028 alt 3 or latest....