Hindustan Petroleum Corporation Limited - Karnataka

33642892 consultancy services for hvac system in satellite rack room consultancy services for hvac system in satellite rack room as per detailed scope of work, terms and conditions. , providing consultancy services for hvac system in substation as per detailed scope of work, terms and conditions. , providing consultancy services for ventilation and ressurisation system in substation as per detailed scope of work, terms and conditions. , providing consultancy services for smoke detection system in substation as per detailed scope of work, terms and conditions. , providing consultancy services for smoke detection system in satellite rack room as per detailed scope of work, terms and conditions. , providing consultancy services for fire suppression system in satellite rack room as per detailed scope of work, terms and conditions. , making visit to site or vendors factory as per instructions of hpcl...

Ministry Of Petroleum And Natural Gas - Karnataka

33622637 bids are invited for consultancy services for hvac system in satellite rack room as per detailed scope of work, terms and conditions. , providing consultancy services for hvac system in substation as per detailed scope of work, terms and conditions. , providing consultancy services for ventilation and ressurisation system in substation as per detailed scope of work, terms and conditions. , providing consultancy services for smoke detection system in substation as per detailed scope of work, terms andconditions. , providing consultancy services for smokedetection system in satellite rack room as per detailedscope of work, terms and conditions. , providingconsultancy services for fire suppression system in satelliterack room as per detailed scope of work, terms andconditions. , making visit to site or vendors factory as perinstructions of hpcl total quantity : 36...

Public Works Department - Karnataka

28655729 annual maintenance of fire hydrant system, smoke detection system, public address system and fire alarm system and allied works in attara kacheri building bangalore for the year 2021 22 (from july 2021 to march 2022) (reserved for sc) a ...

Public Works Department - Karnataka

28655519 annual maintenance of fire hydrant system, smoke detection system, public address system, fire alarm system and allied works in d type judicial staff quarters at byappanahalli, bangalore, ...

Public Works Department - Karnataka

28655381 annual maintenance of fire hydrant system, smoke detection system, public address system and fire alarm system and allied works in high court building bangalore, for the period from july 2021 to march 2022 ...

New Mangalore Port Trust - Karnataka

28059040 comprehensive annual maintenance contract for fire alarm , smoke detection system , cctv , biometric access control system installed at nmpt data centre...

Department Of Space - Karnataka

26321690 tender for comprehensive annual maintenance service contract bor smoke detection and fire alarm system at antgariksh bhavan campus, bengqluru....

Public Works Department - Karnataka

26280811 annual maintenance of fire hydrant system, smoke detection system, public address system and fire alarm system and allied works in city civil court building, bangalore, for the period from april 2020 to march 2021 ...

Union Bank Of India - Karnataka

26041337 annual maintenance contract for access control system/cctv dvr/fire/smoke detection system installed at central office annexe mangaluru & other installations of the bank located in mangaluru city...

Military Engineer Services - Karnataka

23763039 repair / maintenance of fire fighting systems, fire panels / equipment, smoke detctors with allied services at hqtc, bangalore : periodical maintenance and servicing of fire smoke detectors consisting of bentel panel , smoke detectors 8 nos each in a system , fm200 cylinder with 57 kg fm200 gas , realease switches , control switches etc , complete by making regular servicing of the system to ensure proper functioning including replacement of spare materials all as directed . location : af net site i . , maintenance and servicing of 10 hp pump sets 09 numbers fixed in map pocket i&ii complete with motor and starter / panel board for trouble free operation including checking the insulation resistance and electrical contacts and setting right the loose electrical contacts / connection , lubricating the pump set , replacement / tightening of gland packing , arresting leakages in suction / delivery lines etc . including provision of necessary consumables complete all as specified and as directed . notes : ( i ) the spares like bearings , bushes , impellors , couplings , etc , wherever required for replacement shall be measured and paid separately under relevant items of this schedule . ( ii ) the rate quoted deemed to include for replacement of minor spare parts costing upto rs . 200 / each . ( ii ) the contractor shall be responsible for trouble free operation of all the pumpsets during the currency of the contract and shall maintenance and repairs carried out and spares replaced shall be warranted during the contract period . , servicing and testing of ceasefire smoke detection control panel 28 wireless zones , 2 hardwired zone , tamper alert , passcode protected , rf jamming recognition , diagnostic feature for rf signal strength between panel and each detector , event reporting using pstn telephone line , dialing upto 4 telephone numbers , event reporting as per users choice , remote control using telephone line , lcd screen display , intuitive graphic and audible user interface , two way voice interaction , battery backup stand by time upto 12 hrs for 2 nos and in each all as specified and as directed . location : armoury , periodical maintenance and servicing of fire smoke detectors consisting of bentel panel , smoke detectors 8 nos each in a system , fm200 cylinder with 34 kg fm 200 gas , realease switches , control switches etc , complete by making regular servicing of the system to ensure proper functioning including replacement of spare materials all as directed by engineer in charge ( at af net site ii ) , periodical servicing of zone panel and testing of smoke detector fully supervised smoke detector wire less repeater , long life 9 volt alkaline or lithium battery , simple ceiling mount installtion with separate installation bracket for 9 nos in each all as specified and as directed . location : command it section . note for sl item no . 1 to 5 : defect shall be rectified within 24 hours of complaint raised . in any case rectification beyond the stipulated time , penalty shall be levid rs . 500 / per day . , supply and fixing of 12v , 7ah battery for panels in repalcement of old unserviceable batteries all as specified and as directed . make: exide , supply and fix mcp ( manual call point ) glass in replacement of old broken / damaged glass all as specified and as directed . , supply and refilling in cylinder / replacing gas with fm200 gas in cylinder all as specified and as directed . , supply and fix wire less smoke detector of type 1sd12 , operated on 9 volts dc battery complete all as directed . make : cease fire , supply and fix heat detector for max operating temp of 68 degree centigrade , in repair , complete all as directed . , supply and fix fire alarm panel suitable for fm 200 gas extinguishing system , cross zone operated complete testing and commissioning all as directed and specified . make: 5s , supply and fix 1 . 5 sqmm , 2 core flexible armoured copper cable for fire detectors comminication compete all as directed and specified . , supply and fix transformer 50 va , dry type , air cooled , for 12 zone fire alarm conventional panel complete all as directed and specified . make: mini max , supply and fix alkaline dry battery 9 volts , pp3 size , with dura lock complete all as directed . make: duracell or equivalent . , supply and fix timer unit for automatic fire control panel opereated on single phase 230 volts , ac , 50hz complete fixed in repair all as directed and specified . make: selecktron model 800s . , supply and fix thermal over load relay of 10a with max fuse rating at 32a complies to is:9224 operated on single phase 230 volts , ac , 50hz complete in repair all as directed and specified . , supply and fix contactor , continous current rating 40 a , 3 phase , 440 volts complete in repair all as directed and specified . make: c&s . , replacement of manual call point duly painted in red colour with front glass ( to be broken in case of fire ) complete with test key to check he response without breaking the glass and die cast aluminium housing with ifd indicator all as specified . , replacement of zone cards . , spray painting of fire fighting equipment by applying one coat of primer and two coats of synthetic enamel paint of red colour ( post office colour ) all as specified & directed . , supply & fix in replacement of first aid hose fire reel wall mounted type fitted with of dia 20 mm and 30 mtr length , hose with isi marked ss shut of nozzle and connection of 20mm gate valve and pipe complete all as specified and directed . , rewinding of motor up to 10 hp capacity with super enameled copper winding wire of suitable gauge and size , providing insulating materials such as fibre glass tape , varnishing , heating up assembling in the electric motor , testing and commissioning complete including replacement of bearings / bushes by using hydraulic press for testing to full load all as specified and as directed including dismantling & taking to work shop and bring back and re assembling all as directed . , supply and fix ball bearing both end sealed suitable to fix with electric motor of 10 hp capacity fixed in repairs all as specified and as directed . , magnetic sensor suitable for micro processor based digital water level indicator fixed at different levels inside sump / over head reservoir for sensing level of water including dismantling old unserviceable sensor all as directed , pvc insulated copper conductor cable , 12 core x 0 . 6mm gauge , superior quality suitable for carrying signals from sensor to digital water level indicator of approved make including taking down existing un serviceable cable all as specified and directed . make: sunrich , supply and fix fire alarm isi marked including taking down old unserviceable all as directed . , supply and fix single phase preventer suitable for any capacity upto 20 hp pump sets including dismantling and taking up old unserviceable all as specified and directed . make: l&t / minilac , supply and instal digital water level indicator fitted on 25000 ltr capacity fire tanks on airmen map pocket i &ii complete including necessary accessories connecting cables , digital display etc all as specified and directed . , supply & fix in replacement of gun metal coupling assembly with lug ( locking pin ) for hydrant valve complete e all as specified and directed . , supply and fix water pressure guage 100mm dia ranging 0 14 kg / sqcm including dismantling unserviceable exisitng pressure guage complete all as specified and directed . make: accurate , supply and fix in replacement of gun metal one way fire hydrant landing valve of size 63mm dia isi marked complete with instantaneous coupling complete all as specified and...

Indian Space Research Organisation - Karnataka

23589434 comprehensive annual maintenance of contract of smoke detection systems at isite campus comprehensive annual maintenance of contract of smoke detection systems at isite campus safety department installed fire alarm system scope of camc work and building wise detector details are attached herewith as annexure aitf 1 building amc will be effective from: 01.03.2020 safety department installed fire alarm system mgse building safety department installed fire alarm system wet probe facility amc will be effective from: 01.09.2020 safety department installed fire alarm system catvac building amc will be effective from: 01.03.2020 safety department installed fire alarm system catf building amc will be effective from: 01.03.2020...

Military Engineer Services - Karnataka

22484688 repair / maintenance of fire fighting systems , fire panels / equipment , smoke detctors with allied services at hqtc , bangalore , periodical maintenance and servicing of fire smoke detectors consisting of bentel panel , smoke detectors 8 nos each in a system , fm200 cylinder with 57 kg fm200 gas , realease switches , control switches etc , complete by making regular servicing of the system to ensure proper functioning including replacement of spare materials all as directed . location : af net site i . , maintenance and servicing of 10 hp pump sets 09 numbers fixed in map pocket i&ii complete with motor and starter / panel board for trouble free operation including checking the insulation resistance and electrical contacts and setting right the loose electrical contacts / connection , lubricating the pump set , replacement / tightening of gland packing , arresting leakages in suction / delivery lines etc . including provision of necessary consumables complete all as specified and as directed . notes : ( i ) the spares like bearings , bushes , impellors , couplings , etc , wherever required for replacement shall be measured and paid separately under relevant items of this schedule . ( ii ) the rate quoted deemed to include for replacement of minor spare parts costing upto rs . 200 / each . ( ii ) the contractor shall be responsible for trouble free operation of all the pumpsets during the currency of the contract and shall maintenance and repairs carried out and spares replaced shall be warranted during the contract period . , servicing and testing of ceasefire smoke detection control panel 28 wireless zones , 2 hardwired zone , tamper alert , passcode protected , rf jamming recognition , diagnostic feature for rf signal strength between panel and each detector , event reporting using pstn telephone line , dialing upto 4 telephone numbers , event reporting as per users choice , remote control using telephone line , lcd screen display , intuitive graphic and audible user interface , two way voice interaction , battery backup stand by time upto 12 hrs for 2 nos and in each all as specified and as directed . location : armoury , periodical maintenance and servicing of fire smoke detectors consisting of bentel panel , smoke detectors 8 nos each in a system , fm200 cylinder with 34 kg fm 200 gas , realease switches , control switches etc , complete by making regular servicing of the system to ensure proper functioning including replacement of spare materials all as directed by engineer in charge ( at af net site ii ) , periodical servicing of zone panel and testing of smoke detector fully supervised smoke detector wire less repeater , long life 9 volt alkaline or lithium battery , simple ceiling mount installtion with separate installation bracket for 9 nos in each all as specified and as directed . location : command it section . note for sl item no . 1 to 5 : defect shall be rectified within 24 hours of complaint raised . in any case rectification beyond the stipulated time , penalty shall be levid rs . 500 / per day . , supply and fixing of 12v , 7ah battery for panels in repalcement of old unserviceable batteries all as specified and as directed . make: exide , supply and fix mcp ( manual call point ) glass in replacement of old broken / damaged glass all as specified and as directed . , supply and refilling in cylinder / replacing gas with fm200 gas in cylinder all as specified and as directed . , supply and fix wire less smoke detector of type 1sd12 , operated on 9 volts dc battery complete all as directed . make : cease fire , supply and fix heat detector for max operating temp of 68 degree centigrade , in repair , complete all as directed . , supply and fix fire alarm panel suitable for fm 200 gas extinguishing system , cross zone operated complete testing and commissioning all as directed and specified . make: 5s , supply and fix 1 . 5 sqmm , 2 core flexible armoured copper cable for fire detectors comminication compete all as directed and specified . , supply and fix transformer 50 va , dry type , air cooled , for 12 zone fire alarm conventional panel complete all as directed and specified . make: mini max , supply and fix alkaline dry battery 9 volts , pp3 size , with dura lock complete all as directed . make: duracell or equivalent . , supply and fix timer unit for automatic fire control panel opereated on single phase 230 volts , ac , 50hz complete fixed in repair all as directed and specified . make: selecktron model 800s . , supply and fix thermal over load relay of 10a with max fuse rating at 32a complies to is:9224 operated on single phase 230 volts , ac , 50hz complete in repair all as directed and specified . , supply and fix contactor , continous current rating 40 a , 3 phase , 440 volts complete in repair all as directed and specified . make: c&s . , replacement of manual call point duly painted in red colour with front glass ( to be broken in case of fire ) complete with test key to check he response without breaking the glass and die cast aluminium housing with ifd indicator all as specified . , replacement of zone cards . , spray painting of fire fighting equipment by applying one coat of primer and two coats of synthetic enamel paint of red colour ( post office colour ) all as specified & directed . , supply & fix in replacement of first aid hose fire reel wall mounted type fitted with of dia 20 mm and 30 mtr length , hose with isi marked ss shut of nozzle and connection of 20mm gate valve and pipe complete all as specified and directed . , rewinding of motor up to 10 hp capacity with super enameled copper winding wire of suitable gauge and size , providing insulating materials such as fibre glass tape , varnishing , heating up assembling in the electric motor , testing and commissioning complete including replacement of bearings / bushes by using hydraulic press for testing to full load all as specified and as directed including dismantling & taking to work shop and bring back and re assembling all as directed . , supply and fix ball bearing both end sealed suitable to fix with electric motor of 10 hp capacity fixed in repairs all as specified and as directed . , magnetic sensor suitable for micro processor based digital water level indicator fixed at different levels inside sump / over head reservoir for sensing level of water including dismantling old unserviceable sensor all as directed , pvc insulated copper conductor cable , 12 core x 0 . 6mm gauge , superior quality suitable for carrying signals from sensor to digital water level indicator of approved make including taking down existing un serviceable cable all as specified and directed . make: sunrich , supply and fix fire alarm isi marked including taking down old unserviceable all as directed . , supply and fix single phase preventer suitable for any capacity upto 20 hp pump sets including dismantling and taking up old unserviceable all as specified and directed . make: l&t / minilac , supply and instal digital water level indicator fitted on 25000 ltr capacity fire tanks on airmen map pocket i &ii complete including necessary accessories connecting cables , digital display etc all as specified and directed . , supply & fix in replacement of gun metal coupling assembly with lug ( locking pin ) for hydrant valve complete e all as specified and directed . , supply and fix water pressure guage 100mm dia ranging 0 14 kg / sqcm including dismantling unserviceable exisitng pressure guage complete all as specified and directed . make: accurate , supply and fix in replacement of gun metal one way fire hydrant landing valve of size 63mm dia isi marked complete with instantaneous coupling complete all as specified and...

Indian Space Research Organisation - Karnataka

22360782 tender for comprehensive annual maintenance of contract of smoke detection systems at isite campus camc of smoke detection systems at isite campus , for more details visit our website isro . gov . in...

New Mangalore Port Trust - Karnataka

19264212 tender for comprehensive annual maintenance contract for fire alarm system, smoke detection system and other devices installed at nmpt data centre...

Indian Space Research Organisation - Karnataka

17400820 tender for providing power supply to gsat 19 gateway at idsn campus istrac byalalu bangalore electrical works minor works 2 supply, installation, testing and commissioning of power supply panels and smoke detection systems....

Indian Space Research Organisation - Karnataka

17379915 e tender for supply, installation, testing & commissioning of smoke detection system & mine workers 2 power supply panel, providing of gate way co power (electrical work)....

Sri Jayadeva Institute Of Cardiovascular Sciences And Research - Karnataka

15689364 tender for supply of refrigerator –360 ltrs. refrigerator –90 ltrs. 1 no. regulator for ceiling fans` 1 no. round type 1.5 v duracell 1 no. screw driver set – taparia or equivalent 1 no. screw driver set(star&flat) full set screwdriver set full set (star & flat) sealing machine 1 no set box remote 1 no slim tube light – philips(28 watt) t5 1 no. smf batteries 17 ah,12 vsmf batteries 1 no. smoke detection sensor 1 no. smoke detector manual call point sensor mvs24r470ff01 1 no. smoke detector manula response indecator oem/agni 1 no. smoke detector sensor 2351e iptical smoke detector 1 no. smoke hooter sound 110db 1 no. smoke panel upt o 32 detector ravelre 1504/2cd panel 1 no. solder gun 25 watt or equivalent 1 no. soldering fuse 1 big box soldering gum 25watt 1 no soldering lead 1 kg spanner set size: 6 – 32 opened end – taparia or equivalent 1 no. spanner set size: 6 – 32 ring type taparia or equivalent 1 no. spike busters 1 no. stabilizer – servo 1 kva 1 no. stabilizer – servo 2 kva 1 no. stabilizer – servo 3 kva 1 no. stabilizer – servo 4 kva 1 no. stabilizer – servo 5 kva 1 no. stablizer for refrigerator 1 no. starter for tube lights 1 no. switch fuse 3 phase 100 amps 1 no. switch fuse 3 phase 63 amps 1 no.telephone wire 2 pair coil 1 no. threaded lamp 40 watt 220 e 14 volts 1 no. torch – 4 cells 1 no. tube light 4’ 40 w 1 no. ups for computer systems 1 no. ups system 10 kva on line with 30 min back up smf battery 1 no. ups system 15 kva on line with 30 min back up smf battery 1no. ups system 5 kva on line with 30 min back up smf battery 1 no. ups systems 10 kva on line with 6o min back up smf battery 1 no. ups systems 15 kva on line with 6o min back up smf battery 1 no....

Department Of Space - Karnataka

13846395 tender for smoke detection and automatic fire alarm system for advanced technology development facility at isite campus, marathahalli, bengaluru 560037...

Department Of Space - Karnataka

13841813 tender for smoke detection and automatic fire alarm system for advanced heat pipe technology development facility...

South Western Railway - Karnataka

12769978 supply of design,supply, installation, commissioning and maintenance of aspiration type of automatic fire/smoke detection with alarm system. in ac lhb coaches as per rdso/2008/cg 04 rev 03. a .equipment cost including maintenance during warranty period as per clause 6.0 of rdso specification no. rdso/2008/cg 04 rev.03. b installation and commissioning as per para 5.0 of rdso spec. no. rdso/2008/cg 04 rev.03 ....

Department Of Space - Karnataka

12155911 smoke detection, automatic, fire alarm system and flame proof gas detection system for construction of solar panel and battery laboratory...

Department Of Space - Karnataka

12147366 tender for smoke detection, automatic fire alarm, system and public address system for facility buildings in isac campus, bengaluru 560017 h...

Department Of Space - Karnataka

11074233 amsc comprehensive smoke detection and fire alarm system for aitf, catf, catvac, cctv control room & natf buildings as per specification attached for 1st year i.e. from 18 06 2016 to 17 06 2017. subject work is inclusive of supply and repalcement of defective materials as required for maintenance of the system complete as required for trouble free operation and repairs...

Department Of Space - Karnataka

10935978 tender for smoke detection , automatic fire alarm system for vertical extension to sixth floor of c and mg building for student satellite and pmo special projects...

Department Of Space - Karnataka

10927991 comprehensive amsc for smoke detection & fire alarm system for aitf, catf. catvac, cctv control room and nat! buildings...

Department Of Space - Karnataka

10436025 tender for smoke detection , automatic fire alarm system and public address system construction of mechanical system area facility ....